Columbia Boiler MPH 40 HP 2” Tube Bare Boiler Steam boilers

supplied by:

Price: Click To Get Quote

Product Type:
Steam boiler
Competitively-priced, narrow in width & easily serviced, this boiler is a modified Scotch, three-pass fire tube design for use as a 15 PSI steam or 30 PSI water unit. The sizes range from 5 BHP to150 BHP, natural gas or LP gas, #2 oil, dual fuel or biogas fired. Ideal for: breweries, distilleries, schools, apartments, bakeries, brewpubs, laundromats, dairies and many more applications.

MPH Features• 32-1/2” Compact width permits installation through  narrow doors and passageways MPH 5-80• Inverted skid base for forklift handling with low profile• Lifting holes for rigging into tough spots• Bottom hand holes for thorough cleanout• Top hand hole for tube inspection• Cleanout door on flue box• Trim for 15 psi steam or 30 psi water• Low/High/Low standard burner operation MPH 30-125• Modulating burner standard MPH 150, on/off burner MPH 5-20• Natural gas, propane, methane, biogas, oil, or dual fuel firing• Optional hot water coils 300 to 2460 G.P.H.• Overflow tapping for steam unit
• Individual tappings for steam controls• 83%+ efficiency. Economizer package available for high efficiency• Wet base design• Three pass, firetube construction• Welded tubes are schedule 40 pipe for long life13 Gauge rolled tubes are easily replaced• Fully packaged or knocked down• Forced draft firing, no special vent requirements• Constructed in accordance with requirements of Section IV of the  Boiler and Pressure Vessel Code• All boilers are designed, inspected and stamped for conformity to  the requirements of the National Board of Boiler and 
MPH SPECIFICATIONS AND DATA - 15 PSI STEAM / 30 PSI WATERMODEL NO. MPH-40Horsepower 40Gas Input (BTU/hour) 1,680,000Oil Input (Gals./hour) 12Gross Output (BTU/hour) 1,337,600Gross Output Steam (Lbs/hour) 1,380Heating Surface - Sq. Ft. - Pipe 159.0Heating Surface - Sq. Ft. - Tube 138.8Furnace Volume - Cu. Ft. 7.5Water Capacity Steam - Gal. 161Steam Volume - Cu. Ft. 8.9Water Capacity Flooded - Gal. 227Qty. & Length of 2” - 13 ga. Tubes (54) 49-1/4”Hand Hole Quantity & Size (3) 3x3-3/4Standard Burner Electrical 115/1
WATER COIL DATACoil Model Number (1-1/4” Outlet) N4GPM Single Coil - 100° Rise 15GPM Twin Coil - 100° Rise 40
BOILER DIMENSIONS (INCHES)A Bare Boiler (coil plate to drain) 54.6Burner Plate to Rear T/A 66A1 (Turnaround to Turnaround) 71.0B Length (Turnaround to Burner) 92.0C Boiler Width 32.5D Height Supply Outlet 65.5E Minimum Safe Water Level 48.6F Burner Opening to Floor 16.4G Flue Box Height 47.5H Flue Outlet Diameter 10I Safety Valve Opening 1.5 NPTJ Coil Connections to Floor 52.1K Supply Outlet Location 15.3L Supply Outlet Size 4 NPTM Return Inlet Height 21.6N Return Inlet Size 3 NPTO Drain Size 1.5 NPTBoiler Dry Weight - Lbs. 2666
-- [827010] STEAM TRIM MPH10/15
-- [891030] CRT-8 BOILER FEED SYSTEM - Horizontal Low Pressure -- 15PSI steam
-- [827305] GAS BURNER JR50A-12 O/O 
-- [965391] PACKAGE W/J W/TEST
MPH Standard Equipment 
Probe Type Low Water Cut Off and Pump Control, Auxiliary Probe Type LWCO, Operating and Safety Limits, 15 psi ASME Safety Valve and Steam Pressure Gauge.
Manufacturer:Columbia Boiler
Model:MPH  40 HP 2” Tube Bare Boiler

Other Steam Boiler Products